Traffic Exchange Systems are the most popular way on the internet to generate free wibe site traffic. These systems are often referred to as Auto Surf, Manual Surf, Paid Surf or Paid To Click Site.While offering a valuable resource that provides free web site traffic for all your members, you also gain a lot of extra traffic to use for your own sites too ...

Properly managed traffic exchanges are known to experience "high growth rates". New members provide additional income from upgraded accounts and advertising revenue! But, new Members also want to build their own down lines to receive more free traffic, so they will "help" your new system grow much faster by promoting their own referral links!

Can you imagine yourself being "the owner" of a system delivering Thousands of visitors each month for your members ... not to mention your own sites too? It's really not hard to do ... and believe it or not ... you really do not have to be a so-called "Master". In fact, you can do this right now "all by yourself" without any programmers or huge monthly expenses! So if your ready to take that final step to be your own BOSS and run your very own Traffic Exchange (TE), Then check out the options we offer to make it happen! We have a plan to fit anyone's Budget!


Sunday, February 19, 2012

Liquid Penetrant Examinition Procedure

  • Purpose
  1. This procedure provides guidance and acceptance standards for color contrast visible dye penetrant examination of weldments, stainless steel carbon and low alloy steel materials.
  2.  This procedure consists of english versons.
  • Scope 
 This procedure is applicable to the visible solvent removable penetrant systems. Liquid penetrant examination is used to detect discontinuities that are opened to the surface of nonporous metals. Liquid penetrant examination may be performed at the any stages of production in accordance with the written specifications or customer contract requirements.

Procedure Qualification shall be conducted when any change of essential variable stated in table T - 621; changes of nonessential variable stated in table T - 621 need not re-qualification of written procedure. All changes of essential or nonessential variables from the value, specified by the written procedure, it shall require revision of, or an addendum to, the written procedure.

  • Records
Result of Liquid Penetrant Examination Required by the code shall be reported on PT. MSS Penetrant Test report form.

  • References
ASME 2007 Edition 2008 addenda; code sect. I, V, VIII Div. 2, Section IX and ASME B31. 1.
Certification Program for ASME NDE personnel, no. : WP-01.

  • Definitions
Developer : a material that is applied to the test surface to accelerate bleed out and enhance the contrast of the indications.

Penetrant : a solution or suspension of dye.

Footcandle ( fc ) : the illumination on surface, 1 ft in area, on which is uniformly distributed a flux of 1 lm ( lumen ).